Shenzhen Liruisi Electronics Co., Ltd.

Shenzhen Liruisi Electronics Co., Ltd.

Manufacturer from China
Verified Supplier
3 Years
Home / Products / Micro Data Center /

Single Row Module Micro Data Center Energy Saving Capacity Expansion Compatibility

Contact Now
Shenzhen Liruisi Electronics Co., Ltd.
Visit Website
City:shenzhen
Province/State:guangdong
Country/Region:china
Contact Person:MsKelly
Contact Now

Single Row Module Micro Data Center Energy Saving Capacity Expansion Compatibility

Ask Latest Price
Video Channel
Brand Name :lpsrits
Place of Origin :China
MOQ :1 set of
Price :bargaining
Payment Terms :L/C, D/A, D/P, T/T, Western Union, MoneyGram
Delivery Time :8 working days
Packaging Details :The single row scheme of the micro module data center fully considers the standardized design, energy conservation and capacity expansion compatibility, and uses standardized power, refrigeration and cabinet units to help IT experts seamlessly plan, expand
cabenit quanity :LESS THAN 20
ITcabenit quanity :LESS THAN 20
POWER DENITISY -kW/CAbinet :less than15kW/CABINET
Redundancy style :N/N+1/2N
UPSCAPACITY -kVA :MAX90kVA
UPS :rack-mounted modular
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

Single Row Scheme Of Micro Module Data Center Energy Saving And Capacity Expansion Compatibility

Advantages and characteristics

VMDC-06-RRS
cabenit: 1*Integrated cabinet+ 1*IT cabenit

UPS: 6kVA rack-mounted
cooling: 5.6kW InRow air-conditioner

Redundancy:N

Single Row Module Micro Data Center Energy Saving Capacity Expansion Compatibility

VMDC-10-RRS
cabenit 1*Integrated cabinet+ 2*ITcabenit

UPS: 10+10(kVA)rack-mounted

cooling: 7.6+7.6kWInRow air-conditioner

Redundancy: N+1

Single Row Module Micro Data Center Energy Saving Capacity Expansion Compatibility

VMDC-20-RRS
cabenit: 1*Integrated cabinet+ 4*ITcabenit

UPS: 20+20(kVA)rack-mounted

cooling: 17.6+17.6kW InRow air-conditioner

Redundancy: N+1

Single Row Module Micro Data Center Energy Saving Capacity Expansion Compatibility

VMDC-30-RRS
cabenit: 1*Integrated cabinet+ 6*ITcabenit

UPS: 30+30(kVA)rack-mounted

cooling: 25.1+25.1kW InRow air-conditione

Redundancy: N+1

Single Row Module Micro Data Center Energy Saving Capacity Expansion Compatibility

VMDC-40-RRS
cabenit: 1*Integrated cabinet+ 9*ITcabenit

UPS: 40+10(kVA)modular
cooling: 21.2*(2+1)kW
Redundancy: N+1

Single Row Module Micro Data Center Energy Saving Capacity Expansion Compatibility

Technical

monitoring system

model VMDC-06-RRS VMDC-10-RRS VMDC-20-RRS VMDC-30-RRS VMDC-40-RRS ODM
cabenit quanity 2 3 5 7 10 LESS THAN 20
ITcabenit quanity 2 3 4 6 9 LESS THAN 20
POWER DENITISY -kW/CAbinet 2 2 4 4 4 less than15kW/CABINET
Redundancy style N N+1 N+1 N+1 N+1 N/N+1/2N
depth -mm 1400 1400 1400 1400 1400 customization
length -mm 1500 2400 3600 5700 6900 customization
height -mm 2000 2000 2000 2000 2000 less than 2500
POWER SYSTEM
UPSCAPACITY -kVA 6 10+10 20+20 30+30 40+10 MAX90kVA
UPS rack-mounted rack-mounted rack-mounted rack-mounted modular rack-mountedmodular
)battery configuration(1 h) 12V/40Ah 16Pcs 12V/65Ah 16Pcs 12V/65Ah 40Pcs 12V/100Ah 40Pcs 12V/150Ah 40Pcs customization
PDU 32A basic 16 port 32A basic 16 port 32A basic 16 port 32A basic 16 port 32A basic 16 port customization
Total input power specification

63A/1P/220V

/50Hz/60Hz

63A/3P/380V

/50Hz/60Hz

80A/3P/380V

/50Hz/60Hz

125A/3P/380V

/50Hz/60Hz

160A/3P/380V

/50Hz/60Hz

customization
cooling system
cooling style Air cooling Air cooling Air cooling Air cooling Air cooling Air cooling, water cooling and chilled water
air-conditioner configuration-kW 5.6 7.6+7.6 17.6+17.6 25.1+25.1 21.2*(2+1) Per Situation
air-conditioner sytle InRow InRow InRow InRow InRow Row / rack / top mounted
Emergency ventilation Automatic door opening Automatic door opening Automatic door opening Automatic door opening Automatic door opening Automatic door opening
monitoring sysem
monitoring Touch screen Touch screen Touch screen Touch screen Touch screen Optional video, access control, audible and visual / SMS alarm, centralized monitoring, etc
Temperature and humidity Temperature and humidity Temperature and humidity Temperature and humidity Temperature and humidity
UPS management UPS management UPS management UPS management UPS management
air-conditioner management air-conditioner management air-conditioner management air-conditioner management air-conditioner management
smoke detection smoke detection smoke detection smoke detection smoke detection
water leakage water leakage water leakage water leakage water leakage漏水
Door opening status Door opening status Door opening status Door opening status Door opening status

The single row scheme of micro module data center fully considers the standardized design, energy saving and capacity expansion compatibility, and adopts standardized power supply, refrigeration and cabinet units to help it experts seamlessly plan, expand and manage these key infrastructure of data center for the future.

Inquiry Cart 0