Intelligent IP20 UPS Micro Data Center Room Dedicated Single Row System Black

Ask Latest Price
Video Channel
Brand Name :LIRUISI
Model Number :ROW series
Place of Origin :China
MOQ :1 set
Price :negotiation
Payment Terms :L/C, D/A, D/P, T/T, Western Union, MoneyGram
Delivery Time :8 working days
Packaging Details :Cabinet size specification: 600 * 1400 * 2000
Total number of counters :2~ 9 cabinets
PUE value :Less than or equal to 1.2
Dimensions :600*1400*2000
Total IT load capacity :Less than or equal to 36KW
Cooling capacity :Cooling capacity Rack air conditioner: 3.5~ 12.5
emergency refrigeration :Emergency fan
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

LIRUISI-ROW Series Micromodule Room Dedicated Single-Row System Black

Product Introduction:

【 LIRUISI-ROW series integrated single-row data center adopts modular design, which can meet the flexible composition of 1 (1-8) single-cabinet micro-module, directly coupling and splicing between cabinets, forming a double air duct closure on the hot and cold side, integrating the power supply and distribution system, air conditioning system, cabinet system, closed channel system, monitoring system and wiring system, and configuring various environmental data sampling sensors, bringing safe, reliable, compact and convenient computer room deployment experience to unused users.

Application scenarios:

smart finance, smart education, smart healthcare, smart government, smart transportation, smart security, can be applied to dust and wet environments. There is no dedicated computer room space.

Product Features:

2m standard cabinet with larger 42U capacity;Support 1 tow (1-8) cabinet consolidation;There is no need to add additional air duct components, and the cabinets are directly decoupled and assembled to form a "hot and cold dual-channel double-closed" system;Can be installed on cement floor, suitable for five high-floor machine rooms;Ultra-wide voltage range: 138~485V;Ultra-wide temperature range: 40~55°C;

Product parameters:

【LIRUISI-ROW】Technical parameters of intelligent micro-module data center system
Product model LPSRITS-ROW
Performance parameters
Total number of counters 2~ 9 cabinets
Reliability, channel isolation IP20, hot and cold dual channel isolation
PUE value Less than or equal to 1.2
Installation requirements ≥2.3m, support direct installation of cement floor/raised floor (civil buildings can be deployed, no independent room required)
cabinet
Dimensions 600*1400*2000
Total IT load capacity Less than or equal to 36KW
temperature control
Cooling capacity Cooling capacity Rack air conditioner: 3.5~ 12.5
emergency refrigeration Emergency fan
power supply and distribution
Input power system 220V, 50HZ or 380V, 50HZ, support dual inputs
UPS Capacity Rack UPS Rack UPS: 3-90
monitor
Monitoring interface Near-end 10-inch touch screen, web page, client side
Equipment & Environmental Monitoring Air conditioning, power distribution, UPS, temperature and humidity, water leakage detection, smoke detection, door status detection, fire linkage
Intelligent monitoring Battery monitoring, video surveillance, electronic access control, intelligent linkage of external environment refrigeration, multi-site centralized management
fire protection
Rack Fire Protection Heptafluoropropane gas fire protection (optional)
fire extinguishing agent FM200/(optional Novec1230N), 0U bit mounted
Trigger method Fire detection tube (standard) / electronically controlled trigger / third-party fire system trigger / emergency manual button trigger
Note 1: Reis provides customized phone service, the above configuration can be customized and detailed design according to the existing layout, facilities, and needs of the computer room